Return to stove support page for current stove models

Ecoburn Plus 5

Documentation

User Guide Download Aarrow User Guide
Declaration of performance Download Ecoburn Plus 5
Quick Start Guide Download Quick Start Guide
Guide to Wood Burning Download Guide to Wood Burning
Stove Installation Guide Download Room heater / Dry Stove Installation Guide
Product fiche and technical specifications Download Product fiche and technical specifications

Exploded diagram / Spares list

Parts

Diagram no. Part code Part name
1 AFS2345 FIRE DOOR (AFS2345)
2 ARA014 ARADA ROPE KIT 2 (ARA014)
3 AFS1361 GASKET AND GLASS CLIPS (AFS1361)
4 AFS2350 GLASS KIT (AFS2350)
5 AFS1010 GLASS CLIPS (AFS1010)
6 AFS2775 HINGE (RIGHT HAND) (AFS2775)
7 AFS2680 PRIMARY AIR CONTROLS (AFS2680)
8 AFS3575 HANDLE (STAINLESS STEEL)
9 AFS3550 HANDLE ASSEMBLY (STAINLESS STEEL)
10 AFS009 5 INCH FLUE SPIGOT (AFS009)
11 AFS3945 ROPE KIT
12 AFS010 5 INCH HOT PLATE (AFS010)
13 AFS3380 THROAT PLATE
14 AFS2665 LINER (AFS2665)
15 AFS1328 GRATE BAR SUPPORT (AFS1328)
16 AFS2670 LINER (AFS2670)
17 AFS2375 FLEXI GRATE BAR - SMALL (AFS2375)
18 AFS1955 COMB WITH EXTENSION (AFS1955)
19 AFS3940 BASE HEAT SHIELD
20 ARA010 ARADA HOT GLOVE (ARA010)
21 AFS2355 FUEL RETAINER (AFS2355)
22 AFS058 ASH PAN (AFS058)
23 AFS008 OPERATING TOOL (AFS008)

Optional Extras

Part code Part name
ARA017 ARADA ASH CARRIER - MEDIUM (ARA017)
AIB8 ADD IN BOILER - 2.0kW (AIB8)
ADP56 5-6 FLUE INCREASING ADAPTER (ADP56)
AFS3645 BOLT DOWN BRACKETS (PAIR)
AFS151A SPIGOT 5 INCH COMPLETE WITH DAMPER FLAP AND HANDLE (AFS151A)
STAND-ECB5FPLUS STAND FOR ECB5FPLUS
LOG-ECB5FPLUS LOGSTORE FOR ECB5FPLUS
AFS3165 SAFETY HANDLE

General information

Name ECOBURN PLUS 5 FLEXI FUEL G2B
Nominal Output 4.9 kW
Energy Efficiency Class A+
Nett Efficiency 80.3 %
Width 431 mm
Height 550 mm
Depth 365 mm

Product Fiche

Supplier Name or Brand Arada Ltd
Product Code ECB5FPLUS-G2Bsn
Energy Efficiency Class A+
Direct Heat Output 4.9 kW
Energy Efficiency Index 107.4
The useful energy efficiency at nominal heat output and at minimum load 4.9 %
Specific precautions that shall be taken when the local space heater is assembled, installed or maintained Product should be installed in accordance with local building regulations. Appliance will become very hot during use.

Stove output

Wood Performance

Energy Efficiency Class A+
Nett Efficiency 80.3 %
Nominal Output 4.9 kW
Mean Co Emission(@13% O2) 0.39 %
Flue Gas Mass Flow 4.4 g/s
Flue Gas Temperature 306 °C

Smokeless Solid Fuel Performance

Nominal Output 4.9 kW

Dimensions

Assorted dimensions

Width 431 mm
Height 550 mm
Depth 365 mm
Flue Diameter 127 mm
Height of stand 136 mm
Height of log store 386 mm
Total height on stand 686 mm
Total height on log store 936 mm
Height to centre of rear flue 431 mm
Depth from back to centre of top flue 102 mm
Ideal log length 300 mm

Distance to combustible material

Minimum Combustible Distance at Rear 375 mm
Minimum Combustible Distance to Sides 300 mm
Minimum Combustible Distance above 381 mm

Add-in boiler tapping measurements

Add In Boiler Tapping Measurements.
Rear view example shown. Not to scale.

Measurement A 255 mm
Measurement B 264 mm
Measurement C 347 mm
Arada flame picture logo
Top