Dimensions

Height (mm): 542
Width (mm): 573
Depth (mm): 355
Depth into fireplace (mm): -
Height into fireplace (mm): -
Width into fireplace (mm): -
Min. width in fireplace - inset (mm): -
Depth of front fascia - Inset (mm): -
Lintel depth (mm): -
Height (from top to centre of rear flue) (mm): 425
Height of low canopy (mm): 180
Height of high canopy (mm): 260
Height of stand (mm): 200
Total height with stand (mm): -
Height of log store (mm): -
Total height with log store (mm): -
Height of pedestal (mm): -
Total height with pedestal (mm): -
Depth (Back to centre of top flue) (mm): 137
Flue diameter (mm): 127
Flue outlet type:  
Weight - when packed (kg): 80
Weight - when unpacked (kg): -
Ideal log length (mm): 400
Ideal log diameter (mm): -
Top

Distances to combustibles

Min. combustible distance to rear (mm): 760
Min. combustible distance to rear - twin wall flue (mm): -
Min. combustible distance to sides (mm): 500
Min. combustible distance to sides - twin wall flue (mm): -
Min. combustible distance above (mm): 381
Please note: We recommend allowing for a minimum clearance of 100mm to non-combustible materials around the entire appliance.
Top

Features

Current Stove: No
New Product: No
Ecodesign Ready: No
Model version: 3
Wet or Dry stove: Dry
Burns wood fuel: Yes
Burns solid smokeless fuel: Yes
Gas stove: No
Suitable for Smoke Control Areas: No
Stove guarantee: Lifetime
Suitable for a 12mm constructional hearth: Yes
Suitable for direct air installation: No
Stove body type: Freestanding
Top

Output - Wood fuel

Output - wood (kW): 7.5
Output to room - wood - boiler stove (kW): -
Min. output - wood (kW): 1.5
Max. output - wood (kW): 9
Output to water - wood - boiler stove (kW): -
Output to water - wood - boiler stove (BTU): -
Nett Efficiency - wood (%): 71.8
Wood refuelling period:  
Typical wood fuel load to achieve nominal output (kWh/Kg): -
Mean CO Emission - wood (%): 0.33
Particulate Matter - wood (%): -
Mean CH (OGC) Emission - wood (%): -
Mean NOx Emission - wood (%): -
Mean Flue Gas Temperature - wood (deg. C): -
Flue Mass Gas Flow - wood (g/sec): -
Top

Output - Solid smokeless fuel

Output - solid (kW): -
Output to water - solid - boiler stove (kW): -
Output to water - solid - boiler stove (BTU): -
Nett Efficiency - solid (%): -
Typical solid smokeless fuel load to achieve nominal output (kWh/Kg): -
Particulate Matter - solid (%): -
Mean CH (OGC) Emission - solid (%): -
Mean NOx Emission - solid (%): -
Mean Flue Gas Temperature - solid (deg. C): -
Flue Mass Gas Flow - solid (g/sec): -
Top

Output - Gas

Output - gas (kW): -
Min. output - gas (kW): -
Max. output - gas (kW): -
Nett Efficiency - gas (%): -
Min. Nett Efficiency - gas (%): -
Max. Nett Efficiency - gas (%): -
NOx mg per kWh (mg/kWH): -
Top

Direct air information

Direct Air Connection fixed or optional:  
Direct Air Connection Position left to centre distance (mm): -
Direct Air Connection Position right to centre distance (mm): -
Direct Air Connection Position floor to centre distance (mm): -
Direct Air Connection Underneath Position distance from rear (mm): -
Direct Air Connection Positioned Dead Centre?: N
Direct Air Connection diagram type:  
Top

Output - CE Test Figures

CE RATED (nominal) OUTPUT kW: 7.5
CE RATED MIN OUTPUT kW: 1.5
CE RATED MAX OUTPUT kW: 9.0
CE RATED UNDERHEARTH TEMP (deg.C): 61.4
Top

Boiler Tappings

Boiler Tapping Measurement A (mm): 433.5
Boiler Tapping Measurement B (mm): 372
Boiler Tapping Measurement C (mm): 257.5
Boiler Tapping Measurement D (mm): -
Boiler Tapping Measurement E (mm): -
Boiler Tapping Measurement F (mm): -
Boiler Tapping Measurement G (mm): -
Boiler Tapping Measurement H (mm): -
Boiler Tapping Measurement I (mm): -
Boiler Tapping Measurement J (mm): -
Boiler Tapping Measurement K (mm): -
Max Operating Pressure: -
Top

Parts list

  Code Name Type Quantity Optional Extra?
1) VFS034 Fire Door Complete (left) Door 1 No
2) VFS035 Fire Door Complete (right) Door 1 No
3) VFS072 Glass And Gasket Glass and related parts 2 No
4) AFS009 5 Inch Flue Spigot Spigot 1 No
5) AFS010 5 Inch Hot Plate Hot Plate 1 No
6) AFS3370 Throat Plate Throat Plate 1 No
7) VFS023 Liner Liner 2 No
8) VFS029 Liner Liner 2 No
9) VFS128 Operating Tool (4mm) Operating Tool 1 No
10) VFS105 Grate Grate Bar 1 No
11) VFS139 Rocker Arm Comb and Riddle Pull 1 No
12) VFS138 Riddle Bar Comb and Riddle Pull 7 No
13) VFS121 Log Retainer Fuel Retainer 1 No
14) VFS174 Ashpit Door Latch Assembly Handles and Locks 1 No
15) AFS1405 Airwash Knob Handles and Locks 2 No
16) VFS001 Ashpit Door Door 1 No
17) AFS3430 Ashpit Door Slider Air Inlet 2 No
18) VFS110 Ashpit Hinge Pin 2 Inch Hinge 1 No
19) VFS171 Fire Door Latch Assembly Handles and Locks 1 No
20) VFS045 Handle Handles and Locks 2 No
21) ARA013 Arada Rope Kit 1 Arada Brand Accessories 1 No
22) AP502 Ash Pan Ash Pan 1 No
23) AFS2705 Self Levelling Feet Feet 2 No
24) ARA010 Arada Hot Glove Arada Brand Accessories 1 No
25) VFS206 Glass Clip Complete With Nut (pack Of 4) Glass and related parts 1 No
26) VFS112 Hinge Pin 1 Inch Hinge 4 No
1) STAND002 Arada Stove Stand 2 Stand 1 Yes
3) AOCV020 Add On Canopy Low For Fmatew-s3 & Bays-s3 Canopy 1 Yes
4) AOCV021 Add On Canopy High For Fmatew-s3 & Bays-s3 Canopy 1 Yes
5) AIBV009 Add In Boiler - 4.6kw Add In Boiler 1 Yes
6) VFS102 Grate Conversion Plate For Bayswater Elite Accessories 1 Yes
7) AFS1135 Floor Fixing Kit Accessories 1 Yes
8) STAND004 Universal Stand/log Store Log Store 1 Yes

Last updated: 4th February 2020